Line 1: |
Line 1: |
| <big><big><big>'''Adapter Board:ADP-N1 Data Sheet'''</big></big></big> | | <big><big><big>'''Adapter Board:ADP-N1 Data Sheet'''</big></big></big> |
| | | |
− | ==Introduction== | + | ==Product Introduction(产品介绍)== |
| ADP-N1 is a camera interposer module for NVIDIA Jetson AGX Xavier & TX2 DevKit. | | ADP-N1 is a camera interposer module for NVIDIA Jetson AGX Xavier & TX2 DevKit. |
| | | |
− | ==Product Picture== | + | ==Product Picture(产品图片)== |
| {| class="wikitable" | | {| class="wikitable" |
| |'''PART NUMBER / 型号''' | | |'''PART NUMBER / 型号''' |
Line 21: |
Line 21: |
| [[File:ADP-N1-B-PinList.jpg|alt=|thumb|600x600px|ADP-N1 J7 PINLIST]] | | [[File:ADP-N1-B-PinList.jpg|alt=|thumb|600x600px|ADP-N1 J7 PINLIST]] |
| | | |
− | ==Adapter Board Pinlist== | + | ==Adapter Board Pinlist(接口和引脚说明)== |
| {| class="wikitable" | | {| class="wikitable" |
− | | colspan="3" |'''J8:Jumper''' | + | | colspan="3" |'''J8:Funcation Jumper(功能选择)''' |
| |- | | |- |
− | |'''<small>Pin NO.</small>''' | + | |'''<small>Pin NO.(引脚号)</small>''' |
− | |'''<small>NAME</small>''' | + | |'''<small>NAME(名称)</small>''' |
− | |'''<small>Remarks</small>''' | + | |'''<small>Remarks(说明)</small>''' |
| |- | | |- |
| |1 | | |1 |
Line 44: |
Line 44: |
| | colspan="3" |'''J9''' | | | colspan="3" |'''J9''' |
| |- | | |- |
− | |'''<small>Pin NO.</small>''' | + | |'''<small>Pin NO.(引脚号)</small>''' |
− | |'''<small>NAME</small>''' | + | |'''<small>NAME(名称)</small>''' |
− | |'''<small>Remarks</small>''' | + | |'''<small>Remarks(说明)</small>''' |
| |- | | |- |
| |1 | | |1 |
Line 61: |
Line 61: |
| |} | | |} |
| {| class="wikitable" | | {| class="wikitable" |
− | | colspan="2" |'''J8,J9,SW1 Functional specifications''' | + | | colspan="2" |'''J8,J9,SW1 Functional specifications(J8,J9,SW1功能说明)''' |
| |- | | |- |
− | |'''<small>J8 Jumper Status</small>''' | + | |'''<small>J8 Jumper Status(J8跳选状态)</small>''' |
− | |<small>'''Remarks'''</small> | + | |<small>'''Remarks(说明)'''</small> |
| |- | | |- |
| |Short connection J8-1 and J8-2 | | |Short connection J8-1 and J8-2 |
| + | (短接J8的1、2引脚) |
| |Select J7-86(CAM_VSYNC) as the trigger source,Only available Interconnect with TX2 platform | | |Select J7-86(CAM_VSYNC) as the trigger source,Only available Interconnect with TX2 platform |
| + | (与TX2平台主板互联时,此时选择的是J7-86(CAM_VSYNC)作为触发源) |
| |- | | |- |
| | rowspan="2" |Short connection J8-2 and J8-3 | | | rowspan="2" |Short connection J8-2 and J8-3 |
| + | (短接J8的2、3引脚) |
| |Select J9-1(Ext Trigger In) as the trigger source | | |Select J9-1(Ext Trigger In) as the trigger source |
| + | (此时选择的是J9-1(Ext Trigger In)作为外触发源) |
| |- | | |- |
| |SW1 is used for testing to simulate an external trigger signal,Internal Connect with J9-3 | | |SW1 is used for testing to simulate an external trigger signal,Internal Connect with J9-3 |
| + | (此时SW1模拟一个外触发信号,与J9-3引脚连接在一起) |
| |} | | |} |
| {| class="wikitable" | | {| class="wikitable" |
Line 897: |
Line 902: |
| |} | | |} |
| | | |
− | ==Adapter Board Dimension== | + | ==Adapter Board Dimension(板子尺寸)== |
| [[File:ADP-N1-CAD2.jpg|alt=|thumb|600x600px|ADP-N1 CAD / unit:mm|none]][[Media:ADP-N1 DXF.zip|Download dwg file here]] | | [[File:ADP-N1-CAD2.jpg|alt=|thumb|600x600px|ADP-N1 CAD / unit:mm|none]][[Media:ADP-N1 DXF.zip|Download dwg file here]] |
| __FORCETOC__ | | __FORCETOC__ |