Changes

Jump to navigation Jump to search
Line 43: Line 43:  
In normal trigger mode, if multiple frames are triggered at one time, the trigger delay acts after this trigger signal, and the trigger interval and exposure delay are valid before each '''''trigger cycle'''''.
 
In normal trigger mode, if multiple frames are triggered at one time, the trigger delay acts after this trigger signal, and the trigger interval and exposure delay are valid before each '''''trigger cycle'''''.
   −
The following figure shows an example of a trigger with Trigger Number set to 2:<br />
+
The following figure shows an example of a trigger period  with Trigger Number set to 2:<br />
 
[[File:Rolling shutter Normal trigger mode new2.png|alt=|center|thumb|799x799px|Normal trigger mode( Rolling shutter)]]
 
[[File:Rolling shutter Normal trigger mode new2.png|alt=|center|thumb|799x799px|Normal trigger mode( Rolling shutter)]]
<br />
  −
   
===== Global shutter =====
 
===== Global shutter =====
 
TODO
 
TODO
Line 54: Line 52:  
===== Rolling shutter =====
 
===== Rolling shutter =====
 
In high-speed trigger mode, assume '''Trigger Number''' is N, frames 2 to N are output immediately after the previous frame and there is no more trigger interval. This allows the same maximum frame rate to be achieved as in video streaming mode.
 
In high-speed trigger mode, assume '''Trigger Number''' is N, frames 2 to N are output immediately after the previous frame and there is no more trigger interval. This allows the same maximum frame rate to be achieved as in video streaming mode.
 +
 +
The following figure shows an example of a trigger period with Trigger Number set to 3:
 +
[[File:Rolling shutter High-speed trigger mode.png|center|thumb|800x800px|High-speed trigger mode(Rolling shutter)]]
 +
<br />
    
==== Switching of modes ====
 
==== Switching of modes ====

Navigation menu