[[Camera module Stream Mode manual/zh|查看中文]] | [[Camera module Stream Mode manual/zh|查看中文]] | ||
− | === | + | ===Applicable Product models=== |
CS-MIPI-IMX307 | CS-MIPI-IMX307 | ||
− | === | + | ===The concept of stream mode=== |
====free running==== | ====free running==== | ||
− | + | In this mode, the camera module runs on its own. | |
====stream sync mode==== | ====stream sync mode==== | ||
− | + | One camera module is configured in master mode, and the other camera modules are configured in slave mode. | |
− | + | The camera module in master mode outputs XVS and XHS signals, while the camera module in slave mode follows the master module for exposure and output data. | |
− | + | In this mode, the exposure parameters of the camera module can be configured manually or automatically. | |
− | === | + | ===Hardware connection of sync mode=== |
− | ==== | + | ====The method of connecting two cameras ==== |
<br /> | <br /> | ||
− | ====Jetson TX2/Xavier | + | ====Jetson TX2/Xavier 6 cameras connection==== |
<br /> | <br /> |
Revision as of 17:48, 27 March 2020
1 Applicable Product models
CS-MIPI-IMX307
2 The concept of stream mode
2.1 free running
In this mode, the camera module runs on its own.
2.2 stream sync mode
One camera module is configured in master mode, and the other camera modules are configured in slave mode.
The camera module in master mode outputs XVS and XHS signals, while the camera module in slave mode follows the master module for exposure and output data.
In this mode, the exposure parameters of the camera module can be configured manually or automatically.
3 Hardware connection of sync mode
3.1 The method of connecting two cameras
3.2 Jetson TX2/Xavier 6 cameras connection