Line 8: |
Line 8: |
| | | |
| ==== Prepare ==== | | ==== Prepare ==== |
− | You can get the upgrade package for the camera from this [https://app.mediafire.com/4tov5s500gaif link].<br /> | + | You can get the upgrade package for the camera from this [https://app.mediafire.com/4tov5s500gaif link]. The default file name is ProductMode_Version_.bin, for instance MV-MIPI-IMX178M_C1.08_L1.02_upgrade.bin. |
| + | |
| + | Use the veye_i2c_upgrade tool to perform the upgrade operation. For different motherboards, we release the corresponding mv_tools_rpi toolset which contains veye_i2c_upgrade. |
| + | |
| + | The mv_tools_rpi is available on GitHub, for example the tools for the Raspberry Pi platform can be downloaded from this [https://github.com/veyeimaging/mvcam_raspberrypi/tree/main/mv_tools_rpi link]. |
| | | |
| ==== Upgrading ==== | | ==== Upgrading ==== |
| | | |
| + | * Step 1: |
| + | |
| + | Put the upgrade package(MV-MIPI-IMX178M_C1.08_L1.02_upgrade.bin) into the same directory as veye_i2c_upgrade. |
| + | |
| + | * Step 2: |
| + | |
| + | Confirm that the camera module is powered up. |
| + | |
| + | Using v4l2 driver mode, the power up and probe process will be performed during the linux boot process. |
| + | |
| + | In particular, for the legacy mode of the Raspberry Pi, you need to execute camera_i2c_config to power up the camera. |
| + | |
| + | * Step 3: |
| + | |
| + | Please refer to the following article to determine which i2c bus this camera is connected to. |
| + | |
| + | [http://wiki.veye.cc/index.php/I2c_bus_number_and_video_node i2c bus number on different boards] |
| + | |
| + | * Step 4: |
| + | |
| + | For the mv series, execute this command to read the current version: |
| + | |
| + | <code>./mv_mipi_i2c.sh -r -f version -b [i2c bus]</code> |
| + | |
| + | For VEYE-MIPI-IMX335,execute this command to read the current version: |
| + | |
| + | <code>./veye5_mipi_i2c.sh -r -f version -b [i2c bus]</code> |
| + | |
| + | Step 5: |
| + | |
| + | Execute this command to upgrade, and a progress prompt will be displayed during the upgrade.<code>./veye_i2c_upgrade [upgrade package file name] -b [i2c bus]</code><br />Step 6: |
| | | |
− | <code>./veye_i2c_upgrade [filename] -b [i2c bus]</code><br />
| + | After the upgrade is complete, the camera will automatically restart. You can re-read the version number to confirm. |