Line 2: |
Line 2: |
| | | |
| *MV MIPI series (for instance MV-MIPI-IMX178M ...) | | *MV MIPI series (for instance MV-MIPI-IMX178M ...) |
| + | *RAW MIPI series (for instance RAW-MIPI-SC132M ...) |
| *VEYE-MIPI-IMX335 | | *VEYE-MIPI-IMX335 |
| | | |
Line 24: |
Line 25: |
| Confirm that the camera module is powered up. | | Confirm that the camera module is powered up. |
| | | |
− | Using v4l2 driver mode, the power up and probe process will be performed during the linux boot process. | + | Using v4l2 driver mode, the power up and probe process will be performed during the linux boot process. Just power on the board and it should work. |
| | | |
| In particular, for the legacy mode of the Raspberry Pi, you need to execute camera_i2c_config to power up the camera. | | In particular, for the legacy mode of the Raspberry Pi, you need to execute camera_i2c_config to power up the camera. |
Line 44: |
Line 45: |
| <code>./veye5_mipi_i2c.sh -r -f version -b [i2c bus]</code> | | <code>./veye5_mipi_i2c.sh -r -f version -b [i2c bus]</code> |
| | | |
− | Step 5: | + | * Step 5: |
| | | |
| Execute this command to upgrade, and a progress prompt will be displayed during the upgrade. | | Execute this command to upgrade, and a progress prompt will be displayed during the upgrade. |
| | | |
− | <code>./veye_i2c_upgrade [upgrade package file name] -b [i2c bus]</code><br />Step 6: | + | <code>sudo ./veye_i2c_upgrade [upgrade package file name] -b [i2c bus]</code> |
| + | |
| + | If you encounter a situation where the upgrade fails, you can power cycle the camera and then attempt the upgrade again. |
| + | |
| + | * Step 6: |
| | | |
| After the upgrade is complete, the camera will automatically restart. You can re-read the version number to confirm. | | After the upgrade is complete, the camera will automatically restart. You can re-read the version number to confirm. |
| + | |
| + | For the mv series, execute this command to read the current version: |
| + | |
| + | <code>./mv_mipi_i2c.sh -r -f version -b [i2c bus]</code> |
| + | |
| + | For VEYE-MIPI-IMX335,execute this command to read the current version: |
| + | |
| + | <code>./veye5_mipi_i2c.sh -r -f version -b [i2c bus]</code> |
| + | |
| + | * Step 7: |
| + | |
| + | After successful upgrade, it is recommended to restore the factory settings to avoid possible problems caused by the mismatch between the current configuration parameters and the newly upgraded program. |
| + | |
| + | <code>./mv_mipi_i2c.sh -w -f factoryparam -b [i2c bus]</code> |