Difference between revisions of "MV-MIPI-IMX264M Version Log"

From wiki_veye
Jump to navigation Jump to search
 
(One intermediate revision by the same user not shown)
Line 22: Line 22:
 
# Removed the UYVY data type.
 
# Removed the UYVY data type.
 
# D-PHY reset only triggers a power-on reset once, ensuring that each lane is in the LP11 state, which is beneficial for the initialization of the MIPI-RX end, such as Zynq.
 
# D-PHY reset only triggers a power-on reset once, ensuring that each lane is in the LP11 state, which is beneficial for the initialization of the MIPI-RX end, such as Zynq.
 +
 +
* '''MV-MIPI-IMX264M_C1.41_L2.06_upgrade_20240605.bin'''
 +
 +
# In stream mode, the strobe signal is also output.
 +
# Realize precise strobe signal output with very short exposure time.
 +
 +
* '''MV-MIPI-IMX264M_C1.43_L2.07_upgrade_20240912.bin'''
 +
 +
# Add Pulse trigger mode.
 +
# Add frame count function.

Latest revision as of 11:35, 13 September 2024

1 How to get version

MV series MIPI cameras have two version numbers, Using shell script ,get version.

L version is logic version,C version is controller version.

2 Upgrade package download

CS Serials Camera Upgrade Images(Mediafire)

3 Version Log

  • MV-MIPI-IMX264M_C1.20_L1.30_upgrade.bin
  1. First release version.
  • MV-MIPI-IMX264M_C1.26_L1.32_upgrade_20230208.bin
  1. Improve signal integrity of MIPI CSI-2.
  2. Improved AE and AG algorithms.
  3. Solve the problem that imx265 imx264 has a black border at the bottom.
  • MV-MIPI-IMX264M_C1.34_L2.02_upgrade_20231024.bin
  1. Increased the image processing speed of the ISP module, resulting in an enhanced maximum frame rate.
  2. Removed the UYVY data type.
  3. D-PHY reset only triggers a power-on reset once, ensuring that each lane is in the LP11 state, which is beneficial for the initialization of the MIPI-RX end, such as Zynq.
  • MV-MIPI-IMX264M_C1.41_L2.06_upgrade_20240605.bin
  1. In stream mode, the strobe signal is also output.
  2. Realize precise strobe signal output with very short exposure time.
  • MV-MIPI-IMX264M_C1.43_L2.07_upgrade_20240912.bin
  1. Add Pulse trigger mode.
  2. Add frame count function.